JET_32745_com.dat ITER Profile Database; datasets prepared by Pam Stubberfield, August 1996 JET shot 32745 is an ELMy H-mode shot obtained in the new JET pump divertor configuration. This pulse ( 2.8T, 2.9MA ) is 80% deuterium and 20% helium 3. The plasma is in a single-null X-point configuration with the ion gradB drift pointing towards the X-point. Some 8.1MW of 80KV/D and 8.1MW of 140KV/D neutral beam heating is turned on at 54 secs. At 59 secs all 80KV beams are switched off then at 60.0 secs the 140KV power drops to 4.0MW. All beam heating ceases at 61 secs. The dataset files in this subdirectory were prepared from TRANSP run I916 taking into account the up-down asymmetry of the plasma, run by Bernard Balet on 26 July 1996 on the IBM JAC-2 RS6000 workstation based on JET shot 32745 taken on 29 November 1994. All these files have been prepared according to the Standard list of Variables and File Format manual by D.Boucher (7 December 1995). Tools to produce these files from a TRANSP run were provided by Stan Kaye of PPPL. These have only been modified slightly to run on the RS6000 UNIX workstation and to add 40 secs to all time axes. There are 23 1-D Ufiles and 31 2-D Ufiles. All beam related quantities (energy, particle sources, currents etc) have been smoothed to suppress Monte-Carlo noise. In the file JET_32745_0d.dat data is given at 56.44 secs. At that time, there is 16.2MW of beam heating and the plasma is in a steady ELMy H-mode phase and at a sawtooth. Values for kappa and delta in the 0d, 1d and 2d files are from the TRANSP output derived from the boundary input definition provided by EFIT. kappa = (Zmax-Zmin)/(Rmax-Rmin); delta = (RGEO - R(Zmax))/a XPLIM is from XLOC ; SEPLIM is given by EFIT. PLTH is defined by WTH/TAUTH coming directly from TRANSP output and not as defined in the standard list of variables. The 1d files for IP,VSURF and IBOOT have negative values as normal for JET. Some comments on this particular TRANSP run I916; 25ms analysis time resolution; VMEC equilibrium LEVGEO = 6 Up-down asymmetric boundary definition obtained from the EFIT program Sawteeth events are not taken into account in the simulation Ti profile from CX measurements Te profile vs. radius is from combined LIDAR and ECE measurements. Ne profile from combined spectroscopy and LIDAR measurements Nd profile from CX measurements. Radiation profile is used in the analysis. Rotation velocity profile from CX measurements is provided. Zeff profile from CX; impurity species assumed to be carbon Edge ptcl confinement time is set to 1s. Bootstrap current on NLBOOT = T ; impose q(0) = 1.1 to start Neoclassical beam driven current The TRANSP simulation in run I916 results in a predicted W_dia within 0.1MJ of the measured value.